"Norwian Air 800-1000" recuperators
The Norwian Air recuperator with enthalpy heat exchanger is a modern solution with excellent energy efficiency (class A) and a high coefficient of performance (73-75%).
"Norwian Air' means comfort at home
The Norwian Air recuperator is equipped with an enthalpy heat exchanger, which recovers moisture from the exhaust air of the room, keeping the air dry and the indoor humidity comfortable. The smart controller of the plate recuperator “Norwian Air” is included in the standard package.





energy efficiency class: A
efficiency: 73-75%
auto Defrost mode
Sound level: 48dB
A energy class
The enthalpy heat exchanger returns moisture from the exhaust air to maintain comfortable humidity
Temperature recovery efficiency up to 82%
Quiet operation – 48 dB (depending on model)
Extremely quiet and economical DC fans
Full WI-FI control via mobile app
Power consumption (min/max) from 40 W to 225 W
Automatic antifreeze mode
Installed electric heater from 1 kW to 1.5 kW (depending on model
Compact. Mounting methods: ceiling/wall mounted
No drainage required
Duct diameter 160mm /200 mm (depending on model)
*
Improved indoor air quality
Norvian Air recuperators use a double air filter and an enthalpy plate heat exchanger, the plates of which are made of a polymer membrane. The structure of this membrane allows moisture to be returned to the room.
- Washable G4 and Hepa12 filters, captures 99% of solid particles
- Enthalpy heat exchanger allows humidity to be returned to the room
- Significantly more comfortable indoor climate
- Heat recovery efficiency up to 82%
- Cold resistance up to -25 C (with the help of built-in electric heaters)
- No condensation
*
Easy to install
Norwian Air can be installed even in small spaces. Thanks to its compact dimensions (up to 30 cm), Norwian Air can be installed on the ceiling, as well as in a vertical or horizontal position on the wall.
- Optimised component layout
- Convenient access for servicing the device
- No drainage required
- Compact
*
Efficient
The DC fans used in Norwian AIR recuperators are extremely quiet and use little energy. A brushless direct current (BLDC) motor is built into the recuperator fan, which can reduce energy consumption by up to 70%
- Temperature recovery efficiency: 73-82%
- Sound level: 48dB (depending on model)
- Power consumption from 360W to 450W
- Energy efficiency class A
- Longer service life
Wire Controller
Norwian AIR recuperators are equipped with a smart room controller with a high-resolution color screen.
The following functions are integrated in the smart controller: PM2.5 control (indoor air pollution), humidity control, CO2 control, room temperature readings, frost protection, filter contamination, weekly programming.
Control via Mobile App
Norwian Air heat recovery units can be fully WIFI controlled via a mobile app, which allows you to monitor indoor air parameters and control the recuperator remotely using an app on your phone or tablet. Available for iOS and andriod operating systems.
Centralised management (IOT)
Full control via mobile app
Intelligent control according to indoor air quality
Up to 128pcs ERV controlled by one Data acquisition unit Dry contact delay function
Technical details
| Norwian Air 800/1000 recuperators with enthalpy heat exchanger | ||
| Model | Norwian Air 800 | Norwian Air 1000 |
| Air flow (m³/h) at 100Pa | 800 | 1000 |
| Efficiency ratio (%) | 75 | 73 |
| Loudness dB(A) | 48 | 50 |
| Energy consumption without heating function (Electric heater) (W) | 360 | 450 |
| Electric heater (W) | 1500*2 | |
| Power supply (voltage/frequency) | 110-240V / 50(60)Hz | |
| Thermal energy recovery | Iki 82 % | Iki 73 % |
| Filtration efficiency | 99.00% | |
| Control | Room controller with LCD display, mobile app, RS485 interface | |
| Filters | Washable G4 and Hepa12 filters | |
| Operating temperature | -25~40 | |
| Installation | free standing / wall-mounted | |
| Duct diameter | Ø 250 | Ø 250 |
Norwian air 800/1000 connection diagram
Abbreviations
RA, SA, PA, and EA represent the different air streams entering and leaving the unit. They are essential for correctly installing ventilation ducts to ensure proper heat exchange and fresh air supply. Here is the meaning of each:
RA (Return Air): This is the warm, stale, or polluted air being pulled out of the building (from rooms like bathrooms, kitchens, or living areas) and into the recuperator.
SA (Supply Air): This is the fresh, filtered, and pre-heated air that is being supplied into the building rooms.
OA ( Outdoor Air): This is the fresh, cold air being brought in from the outside to be heated by the recuperator.
EA (Exhaust Air ): This is the stale indoor air (formerly RA) after its heat has been transferred to the incoming fresh air, which is then exhausted out of the building.
Norwian air 800 dimensions
* Measurement unit: mm
| Modelis | Norwian Air 800 | Norwian Air 1000 |
| A | 1300 | 1540 |
| B | 1350 | 1583 |
| C | 760 | 780 |
| D | 390 | 390 |
| F | 148 | 148 |
| E | 478 | 558 |
| G | 390 | 390 |
| H | 860 | 880 |
| I | 244 | 244 |
| J | 478 | 426 |
| K | 810 | 810 |
| L | 860 | 860 |
| M | 190 | 280 |
| Ø | 250 | 250 |