SERVICE

Norwian heat pumps are provided with a differentiated 5-year manufacturer’s warranty.
On the condition that the pump is connected to the heating system according to the manufacturer’s recommendations.

Basic warranty conditions

The capacity of the heat pump should be selected according to the heat demand of the building. We strongly recommend consulting with experts before purchasing a heat pump. Norwian pumps have a differentiated warranty: compressors are covered by a 5-year warranty*, other components 2-year warranty.

  • The warranty is provided only if the commissioning and tuning of the equipment was carried out by qualified specialists authorized by the importer. The equipment is installed according to the installation scheme provided by the manufacturer, in accordance with the established requirements. Warranty service is performed for equipment only with a properly filled out and signed by an authorized company commissioning-adjustment act and warranty sheet. Warranty technical service can only be performed by certified specialists.
  •  

* Warranty covered failures:

  1. Faults in the electronic controller.
  2. Compressor and circulation pump failures.
  3. Fan faults.
  4. Refrigerant circuit leak.

Installation scheme of the system with a separate boiler

Montavimo shema su atskiru boileriu

Installation scheme of a system with a multifunctional tank

When installing the heat pump, the total water volume in the heating system and buffer tank must be at least 10 liters per KW of output.
Nr. Meaning NO. Meaning
1 Outdoor Unit 15 Radiator
2 Y-type Filter 16 3# Solenoid 3 way Valve
3 Manual Ball Valve 17 Mixing Water Pump
4 Total System Outlet Water Temp. Sensor 18 Floor Heating Inlet Water Temp. Sensor
5 Auxiliary Heat Source 19 Floor Heating Loop
6 1# Solenoid 3-way Valve 20 Hot Water Tank Temp. Sensor
7 Water Refill Valve 21 Hot Water Tank Electric Heater (Optional)
8 Automatic Exhaust Valve 22 Hot Water Tank
9 Buffer Tank 23 Lower Return WaternPump
10 Buffer Tank Upper Temp. Sensor (Optional) 24 Solar Pump
11 Buffer Tank Lower Temp. Sensor (Optional) 25 Expansion Tank
12 External Circulation Pump 26 Solar Water Temp. Sensor
13 2# Solenoid 3-way Valve 27 Solar Collector
14 Fan Coil