Heat pumps
Energy efficient air to water heat pumps “Norwian Ecoplus” can heat rooms and prepare hot water using significantly less energy than other heating systems.
Norwian pumps are environmentally friendly – they do not emit CO2. The R290 refrigerant used in our pumps is non-toxic, don’t have ozone-depleting properties and have a low GWP (GWP = 3 ) and is 30% more efficient than R32 refrigerant.
Buy a heat pump and get FREE Falcore wired room temperature controller or 2 kW electric heater with a thermostat.
Buy a set – Norwian Ecoplus heat pump with DHW tank “Norwian MWT-C” or multifunctional tank “Norwian MWT“, and receive a GIFT: wireless room thermostat “Falcore” or 3 kW electric heater with a thermostat.
Air to water
Environmentally friendly
Efficient
Long lifetime
A +++ / A++ energy class.
Supply water temperature up to +75°C
Works effectively in heating mode, even the outside temperature drops to -25 °C
*
Efficient
“Norwian Ecoplus” efficient and low energy consumption heat pumps that generate significantly more energy than they themselves consume.
“Norwian Ecoplus” heat pumps are perfect for all types of houses (new construction, old construction and renovation) and can be used with different heating systems (underfloor heating, radiators, fan coils and hot water systems). Therefore, there will be no need to rework the existing heating system.
The combination of R290 refrigerant with DC inverter technology allows the Norwian Ecoplus S heat pump to reach a supply temperature of up to +75 degrees.
- Twin Rotor Inverter Compressor (GMCC)
- Supply water temperature up to +75°C
- Works effectively in heating mode, even when the outdoor temperature drops to -25 °C.
- COP (A7/6℃,W30/35℃) up to 4.67
- SCOP (A7/6℃,W30/35℃) up to 4.89
*
Reliable and Quiet
The Norwian heat pump is extremely quiet, sound pressure level from 37 dB. The DC inverter compressor adjusts the rotation frequency depending on the heat demand, thus reducing the sound level. The following technologies are also used for quieter operation:
- Very quiet operation, only 51/37 dB (at a distance of 1m/5m).
- Integrated electric heater (3 kW-9 kW depending on the model).
- Optimized pipeline design
- Outdoor unit bottom heating cable
- Heated compressor
- Four-way antifreeze function valve
- Components from the world's best manufacturers (Grundfos, Danfoss, GMCC)
*
Economical
The “Norwian Ecoplus” series of heat pumps works on the basis of constant current technology. The technology optimizes the operation of the compressor and ensures comfortable heating with the lowest consumption of electricity, even when the outdoor temperature drops to -25 °C.Norwian pumps use DC inverter technology that can adjust the motor power according to the ambient temperature. This avoids the device turning on and off frequently.
- High efficiency (COP)
- Energy efficiency class A+++
- Constant room temperature
- Longer service life
- Comfortable experience at home
- Compatible with solar power systems
Wire Controller
Wi-Fi Function
Low-maintenance
Technical details
„NORWIAN ECOPLUS“ DC full inverter heat pump R290 (Heating,Cooling,Hot water,WiFi) | ||||
Heating (A 7/6 °C,W30/35 °C ) | ||||
Model | Norwian Ecoplus 60 | Norwian Ecoplus 90 | Norwian Ecoplus 120 | Norwian Ecoplus 160 |
Heating capacity | 1,5-6,27 kW | 2-9,15 kW | 3-12,2 kW | 4-16,2 kW |
Power input | 1,36 kW | 1,99 kW | 2,61 kW | 3,50 kW |
Current | 5,91 A | 8,83 A | 4,41 A | 5,89 A |
COP | 4,62 | 4,58 | 4,67 | 4,61 |
SCOP | 4,71 | 4,89 | 4,77 | 4,77 |
Heating (A 7/6 °C,W47/55 °C ) | ||||
Heating capacity | 6,06 kW | 9,12 kW | 12,20 kW | 16,17 kW |
Power input | 2,03 kW | 3,07 kW | 4,03 kW | 5,30 kW |
COP | 2,99 | 2,97 | 3,03 | 3,05 |
SCOP | 3,71 | 3,72 | 3,73 | 3,75 |
Heating (A 7/6 °C,W40/45 °C ) | ||||
Heating capacity | 6,12 kW | 9,08 kW | 12,03 kW | 16,03 kW |
Power input | 1,71 kW | 2,51 kW | 3,30 kW | 4,98 kW |
COP | 3,58 | 3,62 | 3,65 | 3,22 |
Cooling (A 35/24 °C,W23/18 °C ) | ||||
Cooling capacity | 6,3 kW | 9,02 kW | 11,30 kW | 15,20 kW |
Power input | 1,62 kW | 2,33 kW | 2,91 kW | 3,98 kW |
EER | 3,88 | 3,87 | 3,88 | 3,82 |
Cooling (A 35/24 °C,W12/7 °C ) | ||||
Cooling capacity | 6,2 kW | 8,60 kW | 10,60 kW | 15,05 kW |
Power input | 2,10 kW | 2,92 kW | 3,58 kW | 5,26 kW |
EER | 2,95 | 2,95 | 2,96 | 2,86 |
Rated water flow (m³/h) | 1,1 m³/h | 1,6 m³/h | 2,08 m³/h | 2,8 m³/h |
Ratevoltage(frequency) | 220V-240V~(50Hz) | 220V-240V~(50Hz) | 380V-415V~(50Hz) | 380V-415V~(50Hz) |
Max input power | 2,20 kW | 3,50 kW | 4,70 kW | 6,50 kW |
Max input current | 12,0 A | 15,0 A | 8,0 A | 11,0 A |
Brand/Type of Compresor | GMCC/Rotary | |||
Circulation pump | Grundfos | |||
Circulation pump model | UPM4 K 15-75 130 | UPM4 K 15-75 130 | UPM4 K 25-90130 | UPM4 K 25-90 130 |
Danfoss Plate Heat Exchanger | Danfoss | |||
E.heater | 3 kW single phase | 3 kW single phase | 6 kW three phase | kW three phase |
Expansion vessel | 5 ltr / 5 ltr | |||
Refrigerant (Type) | R290 (propane) | |||
Refrigerant charge | 0,55 kg | 0,75 kg | 1,4 kg | 1,7 kg |
CO2 Equivalent (t) | 0,0016 t | 0,0023 t | 0,0043 t | 0,0051 t |
Defrosting | 4 way valve | 4 way valve | 4 way valve | 4 way valve |
Diameter of water connection | DN 25 (G1“) | DN 25 (G1“) | DN 25 (G1“) | DN 25 (G1“) |
Internal pressure drop at rating flow | 22 kPa | 40 kPa | 50 kPa | 50 kPa |
Waterproof grade | IPX4 | IPX4 | IPX4 | IPX4 |
Min/Max heating water presure | 0.5/3.0 (bar) | 0.5/3.0 (bar) | 0.5/3.0 (bar) | 0.5/3.0 (bar) |
Max water outlet tempereture | 75 °C | 75 °C | 75 °C | 75 °C |
Operating temp. ( heating) | -25/45 °C | -25/45°C | -25/45 °C | -25/45 °C |
Operating temp. ( cooling) | 15/45 °C | 15/45 °C | 15/45 °C | 15/45 °C |
Noise presure (1m/5m) | 51/37 dB 51/37 dB | 53/39 dB 53/39 dB | 54/40 dB 54/40 dB | 56/43 dB 56/43 dB |
Dimensions of the outdoor unit (mm) | 976/450/688 | 1105/450/835 | 1105/450/835 | 1106/450/1603 |
Dimensions of the outdoor unit with packaging (mm) | 1100/455/780 | 1150/455/913 | 1150/455/913 | 1150/455/1671 |
Weight of outdoor unit | 70 kg | 80 kg | 90 kg | 160 kg |
Weight of outdoor unit with package | 80 kg | 90 kg | 100 kg | 175 kg |
Dimensions of the indoor unit (mm) | 386/274/667 | 386/274/667 | 386/274/667 | 386/274/667 |
Dimensions of the indoor unit with packaging (mm) | 425/315/703 | 425/315/703 | 425/315/703 | 425/315/703 |
Indoor unit weight (kg) | 34 kg | 34 kg | 34 kg | 34 kg |
Weight of indoor unit with packaging (kg) | 39 kg | 39 kg | 39 kg | 39 kg |